How to Size a Wire for a Subpanel
Adding a subpanel - for a garage, workshop, addition, or detached structure - starts with correctly sizing the feeder wire that supplies it. Undersized feeders overheat and fail inspection; oversized feeders waste money. This guide walks through the checks that determine minimum wire size.
Step 1: Determine the subpanel's total load
Add up the continuous and non-continuous loads the subpanel will serve - lighting circuits, receptacles, any dedicated appliance circuits (like a shop tool or EV charger). For a simple garage or workshop subpanel, many electricians size for the panel's full bus rating (e.g. a 60A or 100A subpanel) rather than a detailed connected-load tally, especially when future expansion is likely.
Step 2: Check ampacity against the feeder breaker
The feeder conductor's ampacity (corrected for ambient temperature and any conductor bundling - see the Wire Ampacity Calculator) must be at least equal to the feeder breaker size at the main panel. A 60A subpanel feeder breaker requires conductors rated for at least 60A after all correction factors are applied.
Step 3: Check voltage drop over the feeder run
Long feeder runs - common for detached garages or workshops - are frequently limited by voltage drop rather than ampacity. Use the Wire Size Calculator with your subpanel's expected load current, the one-way distance to the subpanel, and a 3% maximum drop target, then compare the result against the ampacity-driven minimum from Step 2 and use whichever is larger.
Step 4: Don't forget the grounding and neutral conductors
A subpanel fed from the same structure typically requires an insulated (not bonded) neutral and a separate equipment grounding conductor run alongside the feeders - bonding neutral and ground at a subpanel, as is done at the main panel, is a common and dangerous code violation that creates parallel neutral return paths.