Dwelling Electrical Load Calculator
Estimate a residential dwelling's total connected electrical load using the simplified NEC 220.82 optional calculation method, and find the recommended electrical service size.
These calculators provide estimates and educational results. Always verify critical engineering calculations against applicable standards and qualified professional review.
Related Calculators
What Is It
Dwelling load calculations determine the minimum electrical service size (amperage) a home needs by summing general lighting load, small appliance and laundry circuits, fixed appliances, and heating/cooling load, then applying a demand factor that recognizes not everything runs at once.
How to Calculate
Enter the home's square footage, number of small-appliance circuits (minimum 2 required), whether there's a dedicated laundry circuit, any other fixed appliance loads, and the larger of the heating or air conditioning load. The calculator sums the general loads, applies the demand factor (100% of the first 10,000 VA, 40% of the remainder), adds the HVAC load at 100%, and recommends a standard service size.
Example
An 1,800 sq ft home with 2 small-appliance circuits and a laundry circuit: general load = (1,800x3) + (2x1,500) + 1,500 = 10,500 VA. Demand load = 10,000 + (500x0.4) = 10,200 VA. Adding an 8,000 VA A/C load gives 18,200 VA total, about 76A at 240V - comfortably served by a standard 100A service.
Recommendations
This optional method applies to a single dwelling unit with a 100A or larger service; larger or multi-family loads typically require the more detailed standard method. Always leave margin for future additions like an EV charger or a heat pump conversion.
Frequently Asked Questions
Last reviewed: 2026-09-12